Connect

 

test

National Restricted Electrical Licence for Airconditioning and Refrigeration Associated Electrical Work

09 Feb National Restricted Electrical Licence for Airconditioning and Refrigeration Associated Electrical Work

Remove that restriction on your Airconditioning and Refrigeration contractor licence and save yourself time and money. This course will qualify you to disconnect and reconnect low voltage composite appliances and rectify faults.

This course meets the requirements for Associated Electrical work for Air Conditioning and Refrigeration Licence requirements.

  • disconnection and reconnection of electrical wiring at the equipment itself and only to the extent necessary to permit the non-electrical work to be performed
  • replacement of equipment on a “like for like” basis
  • testing necessary for the safe isolation of the equipment to be disconnected and reconnected
  • testing necessary for the safe operation of the equipment
  • replacement of ‘blown” fuses and resetting of ‘tripped’ circuit breakers
  • equipment operation at voltages up to 1000V alternating current three phase and 1500V direct current.

To top it off, you now automatically receive Test and Tag National Accreditation.

Course Details

Disconnect Reconnect Composite Appliances

This unit covers disconnecting and reconnecting composite appliances connected to low voltage installation wiring. This may be incidental to or a primary and regular function of work related to a principle work function. It encompasses working safely, identifying supply arrangements, following isolation procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safely testing and reporting.

The unit coverage excludes disconnecting or reconnecting circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of or alteration to any part of the fixed electrical wiring system (defined as electrical installing work).

Note:

Candidates are to meet regulator eligibility requirements by providing formal confirmation from the relevant state/territory regulator for the respective work class and scope of work prior to developing and being conferred competent.

Rectify Faults in Composite Appliances

This unit covers locating and rectifying fault(s) in composite appliances intended to operate to a connected supply up to 1,000 volts a.c. or 1,500 volts d.c. This may be incidental to or a primary and regular function in the workplace. It encompasses following prescribed procedures, working safely, reading circuit diagrams, isolation procedures, identifying faults according to procedures, identifying like for like replacement/repair components according to procedures, selecting and using testing and measuring devices, terminating and connecting cables and conductors, safety testing and reporting.

Note: Limitations of this unit.

This unit does not  cover installations:

a) Where high fault currents are possible,

b) Comprised of complex electrical apparatus and circuits,

c) Associated with fixed wiring other than disconnecting and reconnecting electrical equipment, circuits at a switchboard or to general electrical accessories (including switches, socket outlets, circuit protective devices etc); or installation of or alteration to any part of the fixed electrical wiring system (defined as electrical installing work).listed in the Range Statement of the unit,

d) In hazardous areas or on electrical equipment that is part of an explosion protection technique.

Note:

Candidates are to meet regulator eligibility requirements by providing formal confirmation from the relevant state/territory regulator for the respective work class and scope of work prior to developing and being conferred competent.

Test & Tag

As a part of this course you will also attain accreditation in Test and Tag.

The great thing is, you won’t have to do any additional modules or study as it will be included in the 3 day course. These elements and performance criteria required to meet the requirements set by AS/NZS 3760 the Australian standard on testing and tagging for Test and Tag will be covered.

Test and Tag is perfect for those who work in high-risk environments and need to test items the general public will come in contact with, wanting to start a run test and tag business (ask about our FREE business start up package) and/or if you want to be recognised by insurance companies and auditors as an accredited provider.

Note: Unlike many Test and Tag courses out there, this Test and Tag course is Nationally Accredited.

Outcomes

Upon successful completion of this course you will be awarded a Statement of Attainment in:

SUBJECT CODE UNIT OF COMPETENCY
Disconnect Reconnect UEENEEP012A Disconnect / reconnect composite appliances connected to low voltage installation wiring
Rectify Faults UEENEEP017A Locate and rectify faults in low voltage composite appliances using set procedures

 

Test and Tag will include the following:

SUBJECT CODE UNIT OF COMPETENCY
Test & Tag UEENEEP026A Conduct in-service safety testing of electrical cord connected equipment and cord assemblies
WHS UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace

Can I apply?

Applicants must have completed UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace and either be qualified or licensed in Air conditioning and refrigeration.

Ready to start?

What are you waiting for? Contact Us today. Free call: 1800 765 295. Not what you’re after? See all our qualifications: www.qualifyme.edu.au/qualifications

No Comments

Post A Comment

Not what you're after? See all our qualifications: www.qualifyme.edu.au/qualifications

This qualification is provided by our partner RTO. For more details click here.

Let's Get You Started

Supporting Breast Cancer Research

 

Connect